Refurbished
6 Months Warranty
The STATIM 2000 is a steam autoclave used to sterilize dental instruments. It uses an instrument cassette to process instruments faster than most chamber sterilizers. It features a cassette approximately 3 times smaller than that of the STATIM 5000.
- Fully removable aseptic transport cassette
- Standard STATIM cassette size
- 3 automated sterilization programs
- 14 minute wrapped cycle
- Prolongs instrument life
- Allows user to transport freshly sterilized instruments directly to the procedure area
- Faster sterilization times than chamber autoclave sterilizers
Use only steam-process distilled water in your STATIM. Deionized, demineralized, or specially filtered water should not be used. Never use tap water.
- Dimensions:19″ x 17″ x 6″
- Cassette dimensions:16″ x 7.67″ x 1.6″
- Reservoir volume:140 fl. oz. (4 liters)
- Weight:46 lb.
- Maximum steam temperature:280 °F
- Maximum operating pressure:49.5 PSIA
- Power requirements:● 100V, 50-60Hz, 11A ● 110V, 50-60 Hz, 11A ● 220-240 V, 50-60 Hz, 6A
Overall length w/plug:
20.38″ (51.8 cm)
Overall width:
15.3″ (38.9 cm)
Overall height w/printer:
16.1 in (40.9 cm)
Minimum countertop area:
17.88″ D x 15.3″ W (45.4 cm x 38.9 cm)
Chamber:
9″ diameter (22.9 cm)
15″ depth (38.1 cm)
3.5 gal usable volume (13.4 liters)
Trays:
Two large –
7.3″ W x 12″ L x 0.8″ D
(18.6 cm x 30.5 cm x 2.2 cm)
Two small –
5.6″ W x 12″ L x 0.8″ D
(14.3 cm x 30.5 cm x 2.2 cm)
Pouch Rack:
5-slot pouch rack
1 included with sterilizer
Additional racks available for purchase
Unit weight:
73 lb (33.1 kg)
Shipping weight:
81 lb (36.7 kg)
Water reservoir capacity:
1.1 gal (4.1 liters)
Electrical requirements:
115 VAC, 50/60 Hz, 15 A single phase
115 VAC has 1,425 W tubular immersion heater
230 VAC, 50/60 Hz, 10 A single phase
230 VAC has 1,500 W tubular immersion heater
Installation: Use on a level, water-resistant material such as laminate, stainless-steel or stone. Allow 2.0″ (5.08 cm) on sides and rear, and 5″ (12.7 cm) above to allow space to fill reservoir and change the printer paper roll.
Safety standards:
UL listed to US and Canada standards
UL 61010-1, 2nd edition
IEC 61010-2-040, 1st edition
CAN/CSA C22.2 No. 61010-1, 2nd edition
CSA C22.2 No. 61010-2-040-07, Part 2-040, 1st edition
Meets the requirements of ASME Boiler and Pressure Vessel Code.
A separate (dedicated) circuit is recommended for this sterilizer.
Certifications:
IEC 60601-1-2 Edition 4.0 2014-02
CISPR II:2009, A1:2010 Class A, Group 1
IEC 61000-3-2:2014, Part 3-2
IEC 61000-3-3:2014, Part 3-3
ANSI/AAMI ST55:2010(R)2014
ANSI/AAMI/IEC 62304
Condition: Certified Refurbished