Pre-Owned
Please allow 1 – 2 weeks to ship out.
1 Year Warranty
Compact and lightweight, the ELI™ 280 electrocardiograph provides comprehensive functionality in a portable, touchscreen device. The easy-to-use ELI 280 is designed to meet the demands of high-volume ECG environments.
- Meets newest FAA standards for EKG report submission! (FAA Class I Physicals)
- Best 10 feature automatically selects and displays the best 10 seconds of ECG data from memory, reducing the need for repeat ECGs caused by patient movement or other sources of ECG artifact.
- Comes with the Wired Module.
- Easy bidirectional connectivity allows practices to take orders/send reports with a single keystroke. Choose PDF output, connections to EHR/MIS systems or included DICOM® – our latest connectivity offering that simplifies patient information transfer to data management systems.
- 1,000 sps per channel data capture provides more in-depth ECG signal assessment during analysis, display and printing; 40,000 sps per channel offers unsurpassed pacemaker spike detection.
- ELI 280 Unit
- 10 Lead Patient Cable
- 1 Pack of Paper
- 1 Pack of Electrodes (100 Count)
- 10 Alligator Clips
- Instrument Type: Multi-lead electrocardiograph
- Input Channels: Simultaneous acquisition of all 12 leads
- Standard Leads Acquired: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
- Waveform Display: Backlit, 10.1″ high-resolution color LCD
- Digital Sampling Rate: 40,000 s/sec/channel used for pacemaker spike detection; 1000 s/sec/channel used for recording and analysis
- Optional Functions: VERITAS resting ECG interpretation algorithm with age and gender specific criteria; connectivity with bidirectional communication
- Paper: Perforated Z-fold thermal paper, A4 or 8.5 x 11″ wide, 250 sheets
- Thermal Printer: Computer-controlled dot array; 1 dot/ms horizontal, 8 dots/mm vertical
- Thermal Printer Speeds: 5, 10, 25, or 50 mm/s
- Gain Settings: 5, 10, or 20 mm/mV
- Report Print Formats: Standard or Cabrera: 3+1, 3+3, 6, 6+6, or 12 channel
- Rhythm Print Formats: 3, 6, 8, or 12 channel with configurable lead groups
- Frequency Response: 0.05 to 300 Hz
- Filters: High-performance baseline filter; AC interference filter 50/60 Hz; low-pass filters 40 Hz, 150 Hz, or 300 Hz
- A/D Conversion: 20 bits (1.17 microvolt LSB)
- Device Classification: Class I, Type CF defibrillation-proof applied parts
- ECG Storage: Internal storage up to 200 ECGs
- Weight: 12.5 lbs. (5.68 kg) including battery (without paper)
- Dimensions: 17.5 x 15.5 x 4.5” (44.45 x 39.37 x 11.43 cm)
- Power: Universal AC power supply (100-240 VAC at 50/60 Hz) 110 VA; internal rechargeable battery
Reviews
There are no reviews yet.